Ethernet interface, support Modbus-RTU communication protocol, drive up to 24 dual electronic control valves, CTEU-MBR-24, 007F21

Ethernet interface, support Modbus-RTU communication protocol, drive up to 24 dual electronic control valves, CTEU-MBR-24, 007F21

Order code: 007F21
Order number: CTEU-MBR-24
  • Power interface: M12, male head,4 pins, A code;
  • 通讯接口: M12, 母头,4针,D编码;  M12, 母头,4针,D编码 ; 
  • Support Modbus-RTU communication protocol, drive up to 24 dual electronic control valves
收藏 询盘

Relevant recommendation

  • Functional parameter
  • Resource download
  • Related accessory

Main technical parameters

Dimensions W x L x H  [mm]105.6 x 50 x 39
Fieldbus interface2x M12 socket, 4 pins
Operating voltage Range [V DC]18 -30.2
Maximum power supply [A]4
Maximum number of electromagnetic coils48
Maximum valve number24
Product weight [g]85
Cable length [m]100
Shell materialReinforced polyamide
Notes on materialsComply with RoHS regulations



Pin allocation IO-Link

Pin allocation for power interface针脚分配说明

4P.png

124VLoad power supply (Valve/output)
20VLoad power supply (Valve/output)
324VPower supply (electronic components, sensors/inputs)
40VPower supply (electronic components, sensors/inputs)


specification

  • 007F21 (CTEU-MBR-24) - Specification

    2024-09-20   331.66KB

Operation manual

  • 007F21 (CTEU-MBR-24) - Instructions

    2024-06-03   9.07MB

EPLAN

  • 007F21 (CTEU-MBR-24) -EPLAN (Electrical diagram)

    2024-09-30   1.3MB

Relevant certificate

  • 007F21 (CTEU-MBR-24) -CE certificate

    2024-07-16   226.36KB

Relevant certificate

  • 007F21 (CTEU-MBR-24) -ROHS test report

    2024-08-20   784.74KB
" class="hidden">桃花坞商城